Nnworking of current transformer pdf

This is accomplished using the specialized amorphous core material which minimizes electrical core losses. Commonly used core materials are air, soft iron, and steel. The winding which receives electrical power from the source is known as the primary. The majority of measuring devices have the highest precision. The technique used is based on the finite element method coupled with electric circuits. Current transformers,voltage transformers and instrument. Similarly, current transformers take a high current and reduce it to typically 5 amps on the secondary winding so that it can be used with a watthour meter, ammeter. Apr 16, 2011 current transformers principle of operation of ct a current transformer is defined as as an instrument transformer in which the secondary current is substantially proportional to the primary current under normal conditions of operation and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections. We know that, in a ct the primary current is dependent on the load current or line current as ct is connected in series with the line. The number of secondary winding turns is a selected multiple of the primary turns.

In order to promote public education and public safety, equal justice for all, a better informed citizenry, the rule of law, world trade and world peace, this legal document is hereby made available on a noncommercial basis, as it is the right of all humans to. What is the working principle of a current transformer. Current transformers, or cts, are transformers used to step down the current level of highpower transmission systems to measure or monitor the current levels. In reality, however, it is not possible to neglect the excitation. Current transformer ct construction and working principle. Effects of a current transformer s magnetizing current on the driving voltage in selfoscillating converters.

The primary wire size is much larger than the secondary wire size. The other, a protective current transformer, is used along with. In this video you will learn how a current transformer work. Figure 144 shows the magnetic field during one cycle. Make better business decisions with scalable and converged itot solutions. The current transformer function is different than that of a voltage transformer. It can be designed to step up or step down voltages and works on the magnetic induction principle. The result is a voltage of very small magnitude across the operating coil of the relay. If a ct test switch is used, the switch must have a makebeforebreak contact pattern to. Ring core cts are available for measuring currents from 50 to 5000 amps, with windows power conductor opening size from 1 to 8. Polarity refers to the instantaneous direction of the primary current with respect to the secondary current and is determined by the way the transformer leads are brought out of the case.

Medium voltage mv indoor current transformer ct cable. Current transformers are also used for street lighting circuits. In the typical current transformer application, the primary winding consists of one to a few turns of wire. This is the impedance of the instrument that is connected to the transformer. A current transformer operates with a set primary current and will try to output a constant current to the load, independent of the load. Apr 25, 2017 the current transformer the current transformer c. The electrical current flowing in a transformer is al ternating current. Abstractthis paper discusses the factors to consider for sizing current transformers cts for line protection applications. The classification of protection current transformers follows the following. The byz zerosequence indoor current transformer is used for ground fault detection and is primarily designed for zerosequence overcurrent relaying schemes. In this case the current transformer utilizes a moving secondary coil to vary the output so that a constant current is obtained. Pa current transformers are filled with pcbfree transformer oil. Due to this, it can easily recover from dc magnetization, even with a low ac measured current. The first, a measuring current transformer, is used along with measuring devices for the magnitude of current, energy and power.

According to faradays law of electromagnetic induction, there will be an emf induced in the second winding. It is most commonly used to increase step up or decrease step down voltage levels between circuits. This transformer has a 500 a1 a current ratio and a rated output load of 1 va, which corresponds to a nominal burden of 1. The ct ratio is the ratio of primary current input to secondary current output at full load. The ratio of the current transformer can be modified by altering the number of secondary turns by forward or backwinding the secondary lead through the window of the current transformer.

The magnetic field around the winding is constantly in motion. A current transformer is a device that is used for the transformation of current from a higher value into a proportionate current to a lower value. This paper presents the modeling of a current transformer by various methods with the flux3d software. This is connected in series with the line carrying high current. The object with current transformers is to think in terms of current transformation rather than voltage ratios. In this video you will learn about what is current transformer, important concepts of current transformer, how current transformer work, use of current transformer. Model 276 series current transformers model 276a one.

Magnetization and primary injection test of current. Feb 02, 2017 in this video you will learn how a current transformer work. It also improves the performance of current transformers and subjects their performance to simple calculation. Optical measurements of the arc movement may be difficult to. In the event of an earthfault the sum of the currents is equal to the earthfaul current and a corresponding current flows in the secondary. So, primary current of ct assuming constant line current is constant irrespective of whether the secondary of. A current transformer ct basically has a primary coil of one or more turns of heavy crosssectional area. When the circuit burden gets too large, the ct secondary voltage becomes distorted.

Construction features the ringtype core is fully insulated and toroidally wound. By subtracting turns, the same primary current will result in. We always recommend current transformers with the same precision class for the umg measuring devices. Presentation on current transformers submitted by roopal pancholi b. Current transformers cts provide a simple, inexpensive and yet accurate means of sensing current flow in power conductors.

Model 276a current transformer a low cost, openframe type current transformer ct. While the latter configuration would not be used today, one may be required to make this calculation on an existing system. The basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load. This value is generally given in ohms or va voltamps. Current transformers principle of operation of ct a current transformer is defined as as an instrument transformer in which the secondary current is substantially proportional to the primary current under normal conditions of operation and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections. Sizing current transformers for line protection applications hector j. Msq current transformer technical characteristics of current transformers. Pdf effects of a current transformers magnetizing current. Cts current transformers pts potential transformers. Current transformers theory of operation butler winding. Current transformers reduce high voltage currents to a much lower value and provide a convenient way of safely monitoring the actual electrical current flowing in an ac.

The following table describes the characteristics of the ansi class transformer. Continue reading current transformers theory of operation. Jun 02, 2015 as an example, a typical 100 to 5a current transformer has a nominal ratio of single primary turn to 20 secondary turns or 1. Nov 15, 2019 a current transformer is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current under normal conditions of operation and differs from it by an angle which is approximately zero. They are designed using top core current transformer construction. By adding secondary turns, the same primary current will result in a decrease in secondary output. Current transformers technical datasheet schneider electric is the global specialist in energy management with the most complete power monitoring product line. Under normal operating conditions this sum is zero. Model 276 series current transformers model 276a one primary turn. Simple approach integration of ideal ct secondary voltage the analysis of ct flux levels under the presence of a mix of symmetrical ac and other nonsymmetrical current wave forms, especially if any modeling of ct saturation is to be included, is a rather involved process. For an external fault see figure 3, this allows the current flowing through the current transformer on the line side of the protected zone and the current flowing through the load side current transformers to develop a voltage of opposite polarities. Current transformer basics and the current transformer.

From the above equation, by knowing secondary ammeter current and current ratios, we can easily determine the current flowing through the primary which is connected to the main line. Current transformers are essential components designed to be used with schneider electrics extensive power monitoring product portfolio. In some, the bar carrying high current may act as a primary. For the measurement instrument or protection relay operating via a transformer, in order to operate them. Ring core cts are available for measuring currents from 50 to 5000 amps, with windows power conductor opening size from 1 to 8 diameter. Ecostruxure for your business ecostruxure lets you thrive in todays digital world. The pa current transformers are used in electric power grids with system voltage of up to 145 kv and frequency of 50 hz. Figure 5 shows the result of the curve fitting for core 1, considering the y axis to be the current and x axis to be the voltage, the following expression give the standard. The transformation ratio is the relationship between the primary rated current and the secondary rated current, and is cited on the rating plate as an unsimplified fraction. Selecting current transformers janitza electronics.

The composition of a transformer core depends on voltage, current, and frequency. A distinction has to be made between a metering class and a protection class current transformer. A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. Cts are required because standard current measuring devices are not configured to measu. Current transformers current transformers cts provide a simple, inexpensive and yet accurate means of sensing current flow in power conductors. The arcroot velocity is an important parameter in switchgear devices using magnetically driven arcs for current interruption. Figure 1 gives a circuit schematic of a current transformer application. Model 276b current transformer a ringtype current transformer for currents from 50 to 1200 amps. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load.

Each of these materials is suitable for certain applications. The resultant accuracy depends on these parameters. The basics of current transformers nk technologies. Current transformer errors and transformer inrush as. Nov 17, 2019 a transformer is a static device which transfers electrical energy from one circuit to another through the process of electromagnetic induction. Instrument transformer basic technical information and. Current transformer design guide an effective design of a ring type c. Why the secondary winding of current transformer is always. Turns ratio tests optional test this test is to ensure the turns ratio of ct at all taps. If the primary current changes the secondary current output will change accordingly. A transformer has no moving parts and is a completely. On subtractive polarity transformers the h1 primary lead and the x1 secondary lead will be on the same. Vector diagram of current transformer on noninductive load.

Street lighting requires a constant current to prevent flickering lights and a current transformer is used to provide that constant current. Tech electrical, iii year, v semester k72 submitted to mr. Current transformer grounding powell industries, inc. This is the basic working principle of a transformer. The ip5 a ratio current transformer delivers at the secondary a current is of 0. Sometimes termed transactors and quadrature current transformers, this form of current transformer has been used as an auxiliary component of traditional pilotwire unit protection schemes in which the outputs into multiple secondary circuits must remain linear for and proportional to the widest practical range of input currents. Medium voltage instrument transformers ritz instrument. The result is an extremely accurate ct that can maintain high accuracy over a extended range of. The essentials of current transformers in power circuits. Current transformers can be classified into two separate groups. A current transformer is designed to convert the primary rated current which flows through the primary winding. Equivalent current transformer circuit x 1 primary leakage reactance r 1 primary winding resistance x 2 secondary leakage reactance z 0 magnetizing impedance r. Basics, maintenance, and diagnostics vii contents continued page 4.

If the circuit of this secondary winding is closed, then a current will flow through it. For use with up to 8 gauge wire, and up to 40 amps on the primary. Secondary current will be within 10% accuracy at 120 x rated current with burden levels of 3 ohms or less. Sizing current transformers for line protection applications. The fundamentals of current sense transformer design patrick a. Cattermole typically, the transformer is designed so that the impedance of the primary winding is much greather than the shunt resistance reflected into the primary side and thus the primary impedance is mostly resistive. A study of the current transformer with particular. A current transformer without primary conductor and primary insulation of its own, which can be mounted over an insulated cable or an insulated busbar. They are fully insulated from the high operating voltage of the system and are usually bolted to the current carrying device. Exploring current transformer applications power electronics. The balance point between coil weight and magnetic force may be adjusted to provide the desired output current. The primary current of minimum of 25% rated primary current to be injected on primary side of ct with secondaries shorted and the secondary current can be measured and recorded for all cores limits. Jak0s is a revenue metering current transformer which maintains ieee 0.

Generally, aircore transformers are used when the voltage source has a high frequency above 20 khz. Rudolf current transformer important of burden burden is the impedance of the secondary circuit in ohms and power factor. The current flows first in one direc tion, stops, then reverses and flows in the other direc274 unit 74 transformers tion. Instrument transformers convert signal levels from dangerous high voltage or inconvenient high current, or current at high voltage to levels appropriate for metering. A current transformer is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current under normal conditions of operation and differs from it by an angle that is approximately zero. The current transformer will operate into either a short circuit or a resistive load until the voltage induced is enough to. It transforms the high voltage current into the low voltage current due to which the heavy current flows through the transmission lines is safely monitored by the ammeter. The active elements are located in a hermetic housing inside the head of the transformer. Current monitoring is necessary at frequencies from the 50 hz60 hz power line to the higher frequencies of switchmode transformers that range into the hundreds of kilohertz. Altuve, normann fischer, gabriel benmouyal, and dale finney, schweitzer engineering laboratories, inc. Let us use electrical symbols to help visualize this. The current transformer is designed to connect in series with the line to transform the line current to the standard 5 amperes suitable for the. Most frequently, x 5 a current transformers are used. Bartype current transformer this type of current transformer uses the actual cable or busbar of the main circuit as the primary winding, which is equivalent to a single turn.

The primary selection criteria is the burden placed on the secondary of the transformer. A current transformer is defined as as an instrument transformer in which the secondary current is substantially proportional to the primary current under normal conditions of operation and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections. A phase imbalance produces a secondary current in the byz. The constant current transformer, usually called a regulator, has a movable secondary winding that automatically changes position to provide constant current for any load within its fullload rating. Magnetization and primary injection test of current transformer for protective relaying jacob tsado 8 current transformers.